Sarasota High School Receives New Highly Reflective, Energy Efficient Roofs

Sarasota High School in Florida Receives New Highly Reflective, Energy Efficient Roofs
November 28, 2017 at 6:31 a.m.

The energy efficient roofs are part of a $42 million campus redevelopment project.

Project Overview: Founded in 1913, Sarasota High School in Sarasota, Fla. has undergone several renovations to accommodate its expanding student body. As part of a $42 million campus redevelopment project, the Sarasota County School Board renovated several buildings on the campus. Springer-Peterson Roofing and Sheet Metal based in Lakeland, Fla. was selected for the work.

The roofing contractor recovered the buildings using Polyglass’ Polyfresko® G cap sheet. Polyfresko G is a highly reflective, white granular membrane. It is manufactured with Polyglass’ patent-pending CURE Technology®, a thin film technology that improves the membranes longevity. Membranes with CURE Technology are highly reflective, energy efficient, UV and stain resistant and retain granules longer.

Challenges: The Springer-Peterson crew worked with a tight timeline to complete the 52,000 sq. ft. job. The roof was made up of 11 different roof areas with parapet walls a minimum of 4’ high separating them. Access was minimal on one side of the facility. The expansion joints were located at the walls making them challenging to install.  The crew also had to protect the grass and sidewalks as they worked on the roof.  The project was completed before school reopened in fall 2016.

The Roofing System Selected: Springer-Peterson installed Polyfresko G APP cap sheet to an existing substrate. The system was installed after installing perimeter fastening enhancements to meet uplift requirements. Polyglass’ Polyflash 2C liquid flashing system was used for the details. PolyFlash 2C is a fluid-applied urethane material using a fleece reinforcement which forms watertight flashings at joints, parapets, walls, and other penetrations.

Learn more about Polyglass.

Editor’s note: This profile first appeared on Polyglass’ website.

Check out other Project Profiles from Roofers Coffee Shop.



Recommended For You


Comments

There are currently no comments here.

Leave a Reply

Commenting is only accessible to RCS users.

Have an account? Login to leave a comment!


Sign In
Johns Manville - Banner Ad - JM EPDM FIT SA
English
English
Español
Français

Sign Up for Our E-News!

Join over 18,000 other roofers who get the Week in Roofing for a recap of this week's best industry posts!

Sign Up
RCS - Sidebar - L&L contest
Pli-Dek - Sidebar - Only the Best - June
Georgia-Pacific - Sidebar Ad - HD ISO
Rapid RevOps - Get A Grip - Sidebar Ad Q4
IKO - Sidebar - Summit Grey
People Make Roofing - Kyle & Campbell Thomas - Nov