By Rob Haddock, president of the Metal Roof Advisory Group and CEO and founder of S-5!
Work-related accidents such as falling off a roof can result in serious and fatal injuries. These accidents are common due to construction-related hazards on roofs and improper safety precautions set in place for workers. Many employers in the construction industry violate Occupational Safety and Health Administration (OSHA) safety requirements, particularly with respect to fall protection due to ignorance or inconvenience.
According to the most recent data from the Census of Fatal Occupational Injuries (2021) Bureau of Labor OSHA Statistics program, fatal work injuries recorded in the United States increased by 8.9 percent in 2021 from the previous year, and falls remain the leading cause of work-related deaths in construction.
In the U.S., it is the responsibility of the employer to protect the employee from rooftop hazards, and because job site visits are infrequent and temporary, most employers choose devices that are temporary and portable. In most other places throughout the world, this is not the case. It is the responsibility, rather, of the building owner to provide the means of protection. For this reason, fall protection systems tend to be permanently installed throughout the building’s life. In the U.S., we are beginning to see a trend toward the latter practice.
Although metal roofs are known for their durability, sustainability and versatility, they can be quite slippery, posing a potential fall hazard, leading to serious injury for workers and liability for a business. Add inclement weather like rain or snow, and the risk is elevated for any worker needing roof access.
Whether installing rooftop equipment, accessories such as HVAC, service walkways, solar PV and snow retention, or conducting rooftop inspections, cleaning, maintenance or servicing equipment, rooftop access is necessary year-round. Fall protection ensures safety on that roof.
Many contractors and installers spend hours on metal rooftops and are confident they can easily navigate the terrain. But accidents happen, so a reliable fall protection system is a must. In addition to protecting the company and its employees, OSHA has established a number of requirements professionals must follow so it’s important to select a fall protection system that complies with OSHA regulations.
According to OSHA, fall-arrest systems must be designed to prevent a worker from free falling more than six feet or contacting a lower level, such as the ground or a lower roof plane. In many cases, this requires guardrails or personal fall-arrest systems, which include anchors as secure attachments for the system.
Anchor points
An anchor point can be a single secure attachment used as a fall-arrest system. In this situation, a body harness is connected to the anchor, limiting the falling distance if a worker was to descend over the edge. Anchor points may incorporate one or multiple attachments and can also be paired with travel-restraint lanyards designed to prevent access to the area where a fall hazard occurs.
Another option providing more freedom of movement is called a horizontal lifeline. This system includes multiple anchor points and a connection cable. The anchor points can be installed on a temporary or permanent basis and require some training for proper use.
For fall-arrest systems, OSHA requires the anchorage strength to either be “capable of supporting at least 5,000 pounds per person attached or designed, installed and used under the supervision of a qualified person, as part of a complete personal fall arrest system that maintains a safety factor of at least two.”
Fall-restraint (or travel-restraint) systems must be able to “withstand 3,000 pounds or twice the maximum expected force needed to keep the worker from accessing the fall-hazard area.”
Photo: Walkways and lifeline attached to an anchor point with S-5! clamps and Unistrut (Source: Diversified Fall Protection)
Guardrails
Guardrails are placed around the roof’s perimeter or any unprotected or exposed side to prevent falling off the edge. As passive barriers, guardrails do not require training. When correctly installed, they are extremely reliable. Often permanent fixtures on the roof, guardrails can save money on repeated professional inspections.
Guardrails used for fall protection must be able to withstand a 200-pound force in any outward or downward direction within two inches of the top rail extremity.
Photo: Rooftop walkway and guardrail mounted with S-5! standing seam clamps (Source: Diversified Fall Protection)
Walkways
In large commercial settings, rooftop walkways are another way to keep workers safe when there is equipment or systems on the roof that must be maintained. For example, on the Apple Park headquarters building in California, six miles of walkways were installed in conjunction with a 7.4 MW rooftop solar PV array.
Photo: Rooftop service walkway mounted with S-5! clamps (Source: S-5!)
Given the weight loads the systems need to carry, it is critical to ensure that the rooftop attachments can support the anchors, guardrails or walkways in a safe and reliable manner. The only way to ensure this reliability is to utilize attachments properly load tested, including a factor of safety. Then, engineer the fall protection system using the tested design load information.
The variables involved in metal roofing include profile types, material types, gauges and substrates.
Load testing must take into account all of these factors to be viable. Each situation is unique, and the way an attachment performs on one type of roof is no guarantee it will perform the same way on another. For this reason, it is important to consult attachment load tests that have been performed for the specific roof type and profile. In addition, these tests should be certified through an independent third party, to ensure the results are proven accurate.
Once the exact values are determined, the system can be engineered to withstand the appropriate loads designated by OSHA.
When mounting fall protection, be careful not to compromise the integrity of the metal roof. For a standing seam metal roof, select clamps that are specifically made to fit the seam profile. Source clamps that are produced in an audited facility with quality assurance standards for product consistency. Make sure the clamps are manufactured from corrosion-resistant metals and are metallurgically compatible with the roof material. Additionally, it’s critical to know the reputation of the manufacturer to ensure the system is verified and has been accurately engineered and tested for the loads it must withstand on the specific roof profile.
Choose non-penetrating clamps that rely on a mechanical interlock for superior holding strength while protecting the metal roof from unnecessary holes. For permanent fall protection systems, source clamps that have the durability to last the life of the roof, backed by the manufacturer’s warranty.
S-5! provides reliable clamp and bracket attachments for metal roofs to most of the largest fall protection companies in the world for permanent anchor points, horizontal lifelines, roof walkways, handrails and guardrails. The extensive certified load testing of the company’s products along with their certified manufacturing enables certified system applications in conformity with global safety standards for fall protection.
It’s critical to protect workers from falling off a metal roof – whether installing ancillaries and equipment or conducting inspection and maintenance. OSHA regulations offer multiple fall-protection strategies to choose from including anchor points, guardrails and walkways.
To ensure safety measures provide adequate protection and meet OSHA-identified loads, utilize rooftop clamps that are:
By selecting tested and proven attachment solutions, fall protection systems can be engineered to keep workers safe and truly confident on the roof.
About the Author
Rob Haddock is president of the Metal Roof Advisory Group as well as CEO and founder of S-5!, the leading authority on metal roof attachment solutions. He is a former contractor, award-winning roof forensics expert, author, lecturer and building envelope scientist who has worked in the industry for five decades. For more information, visit www.S-5.com.
Learn more about S-5! in their Coffee Shop Directory or visit www.S-5.com.